Advantages of MEMs Timing Technologies Part 1

Learn how the MEMs resonators are less sensitive to shock and vibration than quartz resonators in this illustrated demonstration. You can also get a closer look at how the newest family of MEMs oscillators in the SiTime’s Elite Platform™ have several architectural advantages over quartz resonators.

Hello. It's Brett Hanebrink with another product training module for SiTime.

Today we're going to cover the advantages of MEMS technologies which is a two-part series. Let's go ahead and get started with Part 1. The mass of MEMS resonator is about 1-1,000 to 1-3,000 that of a quartz resonator depending on the particular quartz resonator blank. This means that MEMS resonators are inherently less sensitive to shock and vibration than quartz resonators, and this fact would be demonstrated on the next two slides which will show phase noise and frequency shift due to vibration.

This graft shows the phase noise comparison of a quartz resonator versus a MEMS resonator, while subjected to a random vibration profile of 7.5 Grms acceleration and vibration frequency from 15 Hz to 2 kHz. Phase noise measures noise in the frequency domain and lower values are therefore better.

As can be seen from the phase noise plot the quartz plot in red shows about 20 dB increase in noise resulting from the random vibration across the frequency range of 15 Hz to 2 kHz mentioned previously. By contrast the MEMS oscillator plot in green shows no discernible increase in noise from the vibration. An increase in noise at 20 dB can result at lower data throughput due to increase in bit errors and in the worst case dropped communication links.

The above plot shows the oscillator response to sinusoidal vibration profile of magnitude 4 G from 15 Hz to 2 kHz. This is measured in units of parts per billion frequency shift per G of acceleration. The MEMS has 3 to 100 times lower sensitivity to sinusoidal vibration than quartz-based oscillators depending on vibration frequency and THUNDER.

The newest family of MEMS oscillators from SiTime named Elite has several architectural advantages over quartz resonators. Central to this architecture is the use of two MEMS resonators: the TempFlat resonator which has a relatively flat frequency versus temperature response and provides reference frequency to the PLL, and the TempSense resonator which has a fairly steep but linear frequency response of -7 ppm per degree C which makes it a great temperature sensor.

These two resonators show the same die substrate with less than 200 μm separation thus ensuring the best possible thermal coupling between them. This level of thermal coupling between the temperature sensor and resonator is not possible on quartz-based oscillators because of the physical separation between the quartz resonator and temperature sensor which resides on the IC containing the oscillator circuit.

But DualMEMS along with the high bandwidth temperature, the digital converter enables the best possible frequency stability in the presence of fast thermal transients. And quartz oscillators, the CMOS die where the temperature sensor resides is mounted on the pack of substrate and connected to the package leads and crystal connections via bond wires.

This physical separation between the temperature sensor and resonator causes significant thermal lag and therefore more frequency stability error during fast thermal transients. There's little that can be done to improve this thermal lag because the temperature sensor cannot be placed on the quartz resonator. By contrast the Elite family of SiTime MEMS oscillators have a dual resonator construction with the TempSense MEMS sharing the same die substrate with the TempFlat with 200 μm separation.

With this close proximity and sharing the same die substrate, the thermal coupling between the temperature sensor and resonator is very tight resulting in very small thermal lag. To complete the MEMS oscillator construction, the DualMEMS resonator is stacked on top of the CMOS die which contains the CMOS circuit elements including sustaining amplifier, TDC and fractional PLL. This is a good place to close out Part 1. 

Please view Part 2 as we begin to show some added benefits to our new Elite products.

관련 상품 참조

SIT9003AI-13-33DB-14.74560Y

SiTime MEMS Oscillators 보기

최신 동영상

죄송합니다. 선택한 필터와 일치하는 결과가 없습니다.

개인정보 보호정책이 업데이트되었습니다. 잠시 시간을 내어 변경사항을 검토하시기 바랍니다. 동의를 클릭하면 Arrow Electronics 개인정보 보호정책 및 이용 조건에 동의하는 것입니다.

당사의 웹사이트에서는 사용자의 경험 향상과 사이트 개선을 위해 사용자의 기기에 쿠키를 저장합니다. 당사에서 사용하는 쿠키 및 쿠키 비활성화 방법에 대해 자세히 알아보십시오. 쿠키와 추적 기술은 마케팅 목적으로 사용될 수 있습니다. '동의'를 클릭하면 기기에 쿠키를 배치하고 추적 기술을 사용하는 데 동의하는 것입니다. 쿠키 및 추적 기술을 해제하는 방법에 대한 자세한 내용과 지침을 알아보려면 아래의 '자세히 알아보기'를 클릭하십시오. 쿠키 및 추적 기술 수락은 사용자의 자발적 선택이지만, 웹사이트가 제대로 작동하지 않을 수 있으며 사용자와 관련이 적은 광고가 표시될 수 있습니다. Arrow는 사용자의 개인정보를 존중합니다. 여기에서 당사의 개인정보 보호정책을 읽을 수 있습니다.